Advanced IOL Calculations Using High-Resolution Scheimpflug and Spectral Domain OCT Imaging in Post-Myopic LASIK Cataract Eyes | ASCRS
Presentation
Advanced IOL Calculations Using High-Resolution Scheimpflug and Spectral Domain OCT Imaging in Post-Myopic LASIK Cataract Eyes
May 2020
Meeting: 2020 Virtual Annual Meeting
Session: SPS-110 Post Refractive Surgery - IOL Calculations
Authors: Neeraj S. Chawla, , Navaneet Borisuth PhD, MD
This content is only available for ASCRS Members

This content from the 2020 ASCRS Virtual Annual Meeting is only available to ASCRS members. To log in, click the teal "Login" button in the upper right-hand corner of this page.

Purpose
To compare the accuracy of a high-resolution Scheimpflug camera-based formula (Potvin-Hill) and a spectral-domain OCT based formula to the ASCRS calculator for previous myopic LASIK eyes undergoing phacoemulsification (PE) with standard (SV) and premium (P) IOLs.

Methods
This is a retrospective nonrandomized clinical cohort study of 170 post-myopic LASIK eyes that underwent PE with PCIOL implantation. Postoperative refractive data were used to compare back-calculated optimum IOL powers (BCO) and to derive the absolute prediction error (AE). We conducted further subanalyses of the relationship between axial length, optimum power IOL, and the Potvin-Hill and OCT formulas. Eyes with corneal pathologies including keratectasia, pterygium, and Fuch's endothelial dystrophy were excluded from the study as were retinal pathologies including epiretinal membranes, age-related macular degeneration, and active diabetic retinopathy.

Results
We implanted 72 SV PCIOLs and 98 P-IOLs (32 toric, 66 EDOF) in 170 post-myopic LASIK eyes undergoing PE. 81.6% and 91.1% of eyes fell within +/- 0.5D and +/-1.0D of target prediction refraction respectively. In descending order, BCO was most accurate for the Barrett True K formula(AE= 0.40), ASCRS Average (0.42), Masket (0.47), Modified Masket (0.53), Potvin-Hill (0.54), Haigis-L (0.54), OCT (0.62), and Shammas (0.67). When compared to the OCT and Shammas formulas, the Barrett True K, ASCRS Average, and Masket formulas demonstrated statistical significance (p<0.001).

Conclusion
The Barrett, ASCRS Average, and Masket formulas outperformed the Potvin-Hill and OCT power calculations although the difference was only statistically significant for the OCT power calculation comparison. The Potvin-Hill formula typically under-predicted optimum IOL power and performed best in eyes with a greater axial length.
View More Presentations from this Session

This presentation is from the session "SPS-110 Post Refractive Surgery - IOL Calculations" from the 2020 ASCRS Virtual Annual Meeting held on May 16-17, 2020.

We use cookies to measure site performance and improve your experience. By continuing to use this site, you agree to our Privacy Policy and Legal Notice.